摘要
Abstract
This article presents a fault diagnosis method based on wavelet analysis in case of locating the fault thyristors in multi-bridge parallel power unit of excitation system.Summarizing three factors that influence the apparent time of singular point:fault time,location of fault thyristors,α (the firing angle) through the simulation of power unit.The usage of wavelet energy entropy,wavelet modulus maxima and the truth table of fault categories can be applied to remove the effect of disturbing factor and unifies all the fault situations with progressive fault diagnosis strategy that reduce the quantity of current sensors,lower the equipment cost and improve the system reliability.According to simulation and experiment,an improvement method was proposed to test the reliability of this method.关键词
多桥并联励磁系统/功率单元/故障诊断/小波分析/小波能谱熵/模极大值Key words
power unit of excitation system/power unit/fault diagnosis/wavelet analysis/wavelet energy entropy/wavelet modulus maximum分类