高压输电线路下方存在平行油气管道,静电感应和电磁耦合产生的感应电压和感应电流会加速管道的腐蚀.文中利用ATP/EMTP仿真软件建立了同塔双回输电线路模型和输油管道的仿真模型,考虑了线路运行电流大小、平行管道长度、土壤电阻率大小、杆塔呼称高度以及管道偏离杆塔中心线距离等因素对感应电压、感应电流分量的影响.研究结果表明:油气管道上的静电感应分量主要受平行金属管道长度、杆塔呼高度和管道偏离杆塔中心线距离的影响;管道上的电磁感应分量主要受运行电流的大小、…查看全部>>

There are parallel oil & gas pipelines under the high-voltage transmission lines,induced voltage and induced current caused by electrostatic induction and electromagnetic coupling accelerates the corrosion of pipeline.Based on electromagnetic transient program(ATP-EMTP),the transmission line model and pipeline model are established,it is considered that the effect of different operation currents,parallel length,mark-height,soil resistivity and pipeline d…查看全部>>