摘要

Abstract

Insufficient power supply reliability of the auxiliary power system of 1036 MW thermal power unit in Huaneng Haimen power plant has caused limited output of the unit. Therefore,this paper analyzes shortages and defects of the auxil-iary power system and discusses influence on the unit by important load power source arrangement,working and backup aux-iliaries power source distribution,reliability of low voltage auxiliary power,logic setting of safety protective section,and so on. According to actual conditions,it proposes solution for optimized transformation. Optimized transformation measures have improved reliability of the auxiliary system and ensured operation stability of important auxiliaries.