港工技术2017,Vol.54Issue(5):107-110,4.DOI:10.16403/j.cnki.ggjs20170528
中外规范下三轴固结不排水试验的对比研究
Comparative Study of Consolidated Undrained Triaxial Tests Specified in GB
Standard and Other International Standards
林容 1张旭光 1杨鸿钧1
作者信息
- 1. 中交第一航务工程勘察设计院有限公司,天津 300222
- 折叠
摘要
Abstract
Triaxial CU tests of three clayey soil samples from Tianjin are carried out to analyze the difference of the consolidated undrained triaxial tests (CU) specified in GB standard (GB/T 50123-1999), British standard (BS 1377) and American standard (ASTM). The test results show a little difference of shear strength index of clayey soil among the above three standards, and the shear strength index defined by GB standard is slightly less than that of American standard and British standard.关键词
三轴固结不排水试验/国标/英标/美标Key words
consolidated undrained triaxial test/GB standard/British standard/American standard分类
建筑与水利引用本文复制引用
林容,张旭光,杨鸿钧..中外规范下三轴固结不排水试验的对比研究[J].港工技术,2017,54(5):107-110,4.