An AC switching system for UPS is developed,and the switching between AC bypass power supply and inverter power supply is realized.The system based on ARM + liquid crystal display(LCD) uses the Cortex-M3 kernel for 32-bit processor STM32F107 as the main control chip,and uses the built-in 12-bit A/D to complete the 7-way voltage and current signals sampling.While monitoring the running status of UPS,according to the different power supply situation,the logical switching of the power supply is controlled to ensure the normal operation of the power system,and the UPS status information is provided to the local LCD for back database analysis.The system has been successfully applied to the practical system,and works reliably and stably,and deserves to have more widespread application.关键词