电力系统自动化2017,Vol.41Issue(19):102-109,8.DOI:10.7500/AEPS20170331002
多电平铁路功率调节器的无源控制方法
Passivity-based Control Method for Multi-level Railway Power Conditioner
摘要
Abstract
In order to control the railway system power quality problems,a multilevel railway power conditioner (MRPC) composed of cascaded H-bridge cells is studied.It can be connected to the traction feeders directly without isolating transformers in the co-phase supply system.The equivalent circuit diagram is derived according to the topology of the MRPC,and mathematical modeling is performed.On this basis,a Euler-Lagrange mathematical model in dq frame is developed by Park transformation (αβ/dq).Furthermore,the passivity of the system is analyzed,and a passivity-based control method is proposed by injecting damping items into the system.Simulation and experimental results show that the proposed control method with its strong robustness can improve the power quality of the traction system.关键词
铁路功率调节器/模块化多电平换流器/负序电流治理/无源控制/欧拉-拉格朗日数学模型Key words
railway power conditioner/modular multilevel converter/negative-sequence current management/passivity-based control/Euler-Lagrange mathematical model引用本文复制引用
闵俊,叶盛,何志兴,马伏军,徐千鸣,罗安..多电平铁路功率调节器的无源控制方法[J].电力系统自动化,2017,41(19):102-109,8.基金项目
国家自然科学基金资助项目(51607062).This work is supported by National Natural Science Foundation of China (No.51607062). (51607062)