铸造技术2017,Vol.38Issue(11):2664-2666,3.DOI:10.16410/j.issn1000-8365.2017.11.029
600MW电站锅炉水冷壁管泄漏原因分析
Water Wall Tube Leakage of 600 MW Power Plant Boiler
孙澎 1赵长存 1吴楠 1孙涛 1韩光1
作者信息
- 1. 国网河北省电力公司电力科学研究院,河北石家庄050021
- 折叠
摘要
Abstract
The macroscopic,chemical composition,microstructure and fracture were investigated,and the 600 MW power plant boiler water wall tube leakage reasons were analyzed.The results show that the key reason of the water wall tube leakage is the fatigue crack of corrosion medium and the thermal stress associative action.The crack is extension from the outer to the inner wall,and it is mainly the wedge intracrystalline failure.关键词
水冷壁/腐蚀/热应力/疲劳裂纹Key words
water wall tube/corrosion/thermal stress/fatigue crack分类
金属材料引用本文复制引用