| 注册
首页|期刊导航|铸造技术|600MW电站锅炉水冷壁管泄漏原因分析

600MW电站锅炉水冷壁管泄漏原因分析

孙澎 赵长存 吴楠 孙涛 韩光

铸造技术2017,Vol.38Issue(11):2664-2666,3.
铸造技术2017,Vol.38Issue(11):2664-2666,3.DOI:10.16410/j.issn1000-8365.2017.11.029

600MW电站锅炉水冷壁管泄漏原因分析

Water Wall Tube Leakage of 600 MW Power Plant Boiler

孙澎 1赵长存 1吴楠 1孙涛 1韩光1

作者信息

  • 1. 国网河北省电力公司电力科学研究院,河北石家庄050021
  • 折叠

摘要

Abstract

The macroscopic,chemical composition,microstructure and fracture were investigated,and the 600 MW power plant boiler water wall tube leakage reasons were analyzed.The results show that the key reason of the water wall tube leakage is the fatigue crack of corrosion medium and the thermal stress associative action.The crack is extension from the outer to the inner wall,and it is mainly the wedge intracrystalline failure.

关键词

水冷壁/腐蚀/热应力/疲劳裂纹

Key words

water wall tube/corrosion/thermal stress/fatigue crack