基于Sirius测量数据的Acrysof Toric人工晶状体临床应用研究

刘玺 李嘉文 李付亮 段平 刘慧 王玉

局解手术学杂志2017,Vol.26Issue(10):754-759,6.
局解手术学杂志2017,Vol.26Issue(10):754-759,6.DOI:10.11659/jjssx.04E017059

基于Sirius测量数据的Acrysof Toric人工晶状体临床应用研究

Clinical application of Acrysof Toric intraocular lens based on Sirius measurement data

刘玺 1李嘉文 1李付亮 1段平 1刘慧 1王玉1

作者信息

  • 1. 第三军医大学第一附属医院西南眼科医院,重庆400038
  • 折叠

摘要

Abstract

Objective To evaluate the effect of corneal curvature based on Sirius measurement on the accuracy of implantation of Acrysof Toric intraocular lens (IOL) and astigmatism correction.Methods In this prospective study,23 patients (36 eyes) with cataract and mild to moderate corneal astigmatism were recruited and underwent phacoemulsification and Acrysof Toric IOL implantation.In the observation group,the corneal curvature value of 19 eyes measured by Sirius was used as the basis for calculating Acrysof Toric intraocular lens power.In the control group,the corneal curvature value of 17 eyes measured by manual corneal curvature was used as the basis for calculating Acrysof Toric intraocular lens power.Main outcome measurements including uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA) surgically induced astigmatism(SIA),deviation of lens axis (LAD),index of corrected astigmatism (CAI) at 3 months postoperatively were observed.Results At 3 months postoperatively,the average UCVA of the observation group was (0.8 ± 0.11) and the average UCVA of the control group was (0.7 ± 0.73),there was no statistically significant differences (Z =1.277,P =0.372).The average BCVA of the observation group was (0.8 ± 0.21),and the average BCVA of the control group was (0.8 ± 0.41),there was no statistically significant differences (z =0.962,P =0.329).The deviation of lens axis of the observation group was (2.81 ± 1.72) ° and it was (3.12 ± 1.56)°in the control group,and there was no statistically significant differences (t =0.481,P =0.631).The index of corrected astigmatism of the observation group was (1.01 ± 0.21) and it was (1.03 ±0.32) in the control group,with no statistically significant differences (t =0.581,P =0.615).Conclusion Compared with the manual keratometer,Acrysof Toric IOL calculation based on Sirius measurement data is accurate and reliable.Meanwhile,Sirius has obvious advantages such as high resolution,non-contact,non-invasive and easy to operate.

关键词

白内障/散光/晶体/超声乳化白内障吸除术/晶体植入术

Key words

cataract/astigmatism/lenses/phacoemulsification/lens implantation

分类

医药卫生

引用本文复制引用

刘玺,李嘉文,李付亮,段平,刘慧,王玉..基于Sirius测量数据的Acrysof Toric人工晶状体临床应用研究[J].局解手术学杂志,2017,26(10):754-759,6.

局解手术学杂志

OACSTPCD

1672-5042

访问量0
|
下载量0
段落导航相关论文