理化检验-物理分册2017,Vol.53Issue(11):837-840,4.DOI:10.11973/lhjy-wl201711017
导热油管断裂失效分析
Fracture Failure Analysis of a Heat-Transfer Oil Pipe
彭家政 1陈炜 1邱康勇 1张杰1
作者信息
- 1. 深圳市特种设备安全检验研究院,深圳 518029
- 折叠
摘要
Abstract
A heat-transfer oil pipe of a company fractured during use.The methods of macroscopic observation,chemical composition analysis,metallographic inspection,hardness testing and fracture analysis were used to analyze fracture reasons of the heat-transfer oil pipe.The results show that:the heat-transfer oil pipe was repaired by liquid iron containing high carbon,and it increased the brittleness of the material;under the exogenic action,the heat transfer pipe cracked at the position of the thin wall,which led to the heat-transfer oil leak;under the action of the heat-transfer oil pressure,the heat-transfer oil pipe cracked along the cross section.关键词
导热油管/断裂/高碳铁液修补/热力作用Key words
heat-transfer oil pipe/fracture/repair by liquid iron containing high carbon/thermodynamic action分类
矿业与冶金引用本文复制引用