摘要
Abstract
The testing rig of heat-pipe PV/T heat pump system was constructed. Two working modes, heating mode and heat charging mode, were designed. The daily performance of two working modes was studied in two working days with equivalent daily average solar radiation and ambient temperature. The results showed that the average electrical efficiency, thermal efficiency, COPth and COPpv/t of heat-pipe PV/T heat pump system were 12.2%, 33.9%, 2.52 and 3.26 respectively under the heating mode, and the electrical efficiency of PV/T system is improved by 25.7%compared with independent PV panel; While the above performance parameters were 12.9%, 25.3%, 1.82 and 2.33 respectively under the heat charging mode, and the electrical efficiency was improved by 14.2% compared with independent PV panel. The performance of heating mode was better than that of heat charging mode.关键词
热管/PV/T/热泵系统/COPKey words
PV/T/heat pump/heat pipe/COP分类
能源科技引用本文复制引用