| 注册
首页|期刊导航|中国电力|中国1000MW等级火力发电机组可靠性分析

中国1000MW等级火力发电机组可靠性分析

李建锋 周宏 吕俊复

中国电力2017,Vol.50Issue(11):1-7,7.
中国电力2017,Vol.50Issue(11):1-7,7.DOI:10.11930/j.issn.1004-9649.201706097

中国1000MW等级火力发电机组可靠性分析

Reliability Analysis of 1 000 MW Thermal Power Generating Units in China

李建锋 1周宏 1吕俊复2

作者信息

  • 1. 中国电力企业联合会,北京 100761
  • 2. 清华大学热科学与工程教育部重点实验室,北京 100084
  • 折叠

摘要

Abstract

The times and total duration of forced outages of thermal power units with the capacity of 1 000 MW between 2012 and 2016 are counted and analyzed.There are 166 forced outages for all the units,and the total duration is 9 440.22 hours.The times of forced outages caused by boilers and their auxiliary equipments are 78 and the total duration is 5 409.22 hours,accounting for 57.30% of the total forced outage time;while that caused by the turbine systems are 42 and the total duration is 3 060.85 hours,accounting for 32.42% of the total forced outage time.The analysis of technical and liability reasons of the forced outages helps to find out the relative weakness which lowers the unit operating reliability and provides the reference and basis for improving the routine maintenance and management.

关键词

1000 MW等级/火电机组/可靠性/非计划停运/锅炉/汽轮机/发电机

Key words

1 000 MW grade/thermal power unit/reliability/unplanned outage/boiler/turbine/generator

分类

信息技术与安全科学

引用本文复制引用

李建锋,周宏,吕俊复..中国1000MW等级火力发电机组可靠性分析[J].中国电力,2017,50(11):1-7,7.

中国电力

OA北大核心CSCDCSTPCD

1004-9649

访问量0
|