GIS may produce very fast transient enclosure voltage (TEV) in switching operation to cause electromagnetic compatibility problem in substation's secondary system.In this study,a test circuit and a measurement system for the very fast TEV were developed,and the influence of the wiring connection of the TEV point,the reference zero potential point and the measurement device on the TEV measurement accuracy was analyzed.A guiding principle and a recommended circuit for the TEV measurement were proposed.It is suggested that:connecting a large size conductor on GIS enclosure should be avoided in TEV measurement to avoid making change of the original TEV;voltage connecting wire should transmit reference zero potential instead of TEV to the measurement device to avoid causing distortion of TEV waveform.关键词
全封闭气体绝缘开关设备(GIS)/瞬态壳体电压(TEV)/测量/电磁兼容Key words
gas insulated switchgear (GIS)/transient enclosure voltage (TEV)/measurement/electromagnetic compatibility引用本文复制引用
赵鹏程,蔡元纪,雷林绪,何嘉希,刘卫东..电力设备特快速TEV测量方法研究[J].高压电器,2017,53(12):8-13,6.基金项目