高压电器2017,Vol.53Issue(12):236-240,246,6.DOI:10.13296/j.1001-1609.hva.2017.12.038
GIS现场耐压试验与相关设计问题分析
Discussion About Field Withstand Voltage Test of GIS and Related Design Issues
穆焜 1秦莹 1李勇1
作者信息
- 1. 中国电建集团成都勘测设计研究院有限公司,成都610072
- 折叠
摘要
Abstract
To ensure accomplishment of field test for high-voltage switchgears,the issues about field withstand voltage test of GIS are researched according to the method in related test specification for designs of hydropower station and equipment bidding referring to GIS.The schemes about underground GIS with different types of leading conductor and ground GIS are proposed,and some important issues referring to the space design of GIS room,the design of civil structure and the matched equipment of GIS for test are discussed.关键词
水电站/GIS/现场耐压试验Key words
hydropower station/GIS/field withstand voltage test引用本文复制引用
穆焜,秦莹,李勇..GIS现场耐压试验与相关设计问题分析[J].高压电器,2017,53(12):236-240,246,6.