To ensure accomplishment of field test for high-voltage switchgears,the issues about field withstand voltage test of GIS are researched according to the method in related test specification for designs of hydropower station and equipment bidding referring to GIS.The schemes about underground GIS with different types of leading conductor and ground GIS are proposed,and some important issues referring to the space design of GIS room,the design of civil structure and the matched equipment of GIS for test are discussed.

关键词

水电站/GIS/现场耐压试验

Key words

hydropower station/GIS/field withstand voltage test