| 注册
首页|期刊导航|中国组织工程研究|HXN型微创椎弓根螺钉系统经伤椎固定治疗胸腰椎骨折

HXN型微创椎弓根螺钉系统经伤椎固定治疗胸腰椎骨折

王经宇 董玉珍 安永博 崔明星 李清江

中国组织工程研究2017,Vol.21Issue(35):5616-5621,6.
中国组织工程研究2017,Vol.21Issue(35):5616-5621,6.DOI:10.3969/j.issn.2095-4344.2017.35.007

HXN型微创椎弓根螺钉系统经伤椎固定治疗胸腰椎骨折

Vertebral fixation with minimally invasive HXN pedicle screw system for thoracolumbar fractures

王经宇 1董玉珍 1安永博 1崔明星 1李清江1

作者信息

  • 1. 新乡医学院第一附属医院骨科,河南省新乡市 453100
  • 折叠

摘要

Abstract

BACKGROUND: Open reduction and internal fixation have been used to treat thoracolumbar fractures, which possesses good efficacy, but causes large trauma and many complications. Minimally invasive treatment like Wiltse operative approach and Sextant, Zina system also has many defects such as large incision, insufficient fixed strength, limited orthopedic forces. OBJECTIVE: To access the effect of vertebral fixation with HXN pedicle screw system in the treatment of thoracolumbar fractures. METHODS: Totally 68 cases of thoracolumbar fractures admitted in the Department of Orthopedics, the First Affiliated Hospital of Xinxiang Medical University from October 2014 to December 2016 were randomly divided into two groups: the patients in group A received minimally invasive pedicle screw fixation with HXN system and those in group B were subjected to open reduction and internal fixation. The perioperative indexes (blood loss), Visual Analogue Scale scores, Oswestry Disability Index, anterior vertebral height, and Cobb angle were detected to compare the curative efficacy between two RESULTS AND CONCLUSION: (1) All patients were followed up for 3-24 months. (2) There were no significant differences in the operation time, intraoperative fluoroscopy times between two groups (P > 0.05), and the blood loss in the group B was significantly more than that in the group A (P < 0.05). (3) The preoperative Visual Analogue Scale and Oswestry Disability Index scores showed no significant differences between two groups (P > 0.05), and the postoperative and last follow-up scores were significantly decreased (P < 0.05), but the group A had lower scores than those in the group B (P < 0.05). (4) The anterior vertebral height and Cobb angle were significantly improved postoperatively (P <0.05); at the last follow-up, both indexes had no obvious loss and showed no significant difference between two groups (P > 0.05). (5) The incision healed well in the group A, while there were two cases of incision infection in the group B. No screw loosening, displacement or rupture occurred during follow-up. (6) These results suggest that the minimally invasive HXN pedicle screw system for thoracolumbar fracture not only has the advantages of fewer traumas, less blood loss, low incidence of incision infection, pain relief, but also is safe and easy to operate, which obtains good fixation stability and can achieve the same curative effect with the open surgery.

关键词

骨科植入物/脊柱植入物/微创/胸腰椎骨折/椎弓根钉/经皮/实心钉/内固定/椎旁肌/伤椎

分类

医药卫生

引用本文复制引用

王经宇,董玉珍,安永博,崔明星,李清江..HXN型微创椎弓根螺钉系统经伤椎固定治疗胸腰椎骨折[J].中国组织工程研究,2017,21(35):5616-5621,6.

基金项目

2014年度河南省医学科技攻关计划项目(201403141)the Key Medical Science Research & Research Program of Henan Province in 2014, No. 201403141 (201403141)

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文