Abstract

Background harmonic source equivalence is the key to the system harmonic impedance estimation.Fluctua-tion quantity method,fluctuation normalization method and dominant fluctuation screening method to estimate the har-monic impedance are widely used in engineering, but the error can not be tracked during the process of solving.In view of the above defects,this paper proposes a dual filter three point method for the estimation of the system harmonic impedance.Linear regression analysis was performed by using a set of three data points.By the first screening, we choose the regression error to meet the accuracy of data,and then,through the Nair test for the second screening,we select the user side as the leading data, finally, we can find the background harmonic.It proves that the method is correct and effective through the calculation of the measured data.

关键词

电能质量/谐波/系统谐波阻抗/三点法/筛选

Key words

power quality/harmonic/system harmonic impedance/three point method/screening