化工进展2018,Vol.37Issue(1):96-104,9.DOI:10.16085/j.issn.1000-6613.2017-0734
供水温度对高背压热电联产系统能耗水平的影响
Impacts of water supply temperature on energy consumption of high back pressure cogeneration system
摘要
Abstract
Heat supply is effective to improve the overall efficiency and reduce the coal consumption rate in air-cooled power plants. A key issue about design optimization of cogeneration system is to determine the optimal values of the designed primary network water supply temperature,based on the performance variation of overrall system resulting from the temperature of supply water in the primary network. The heat transfer efficiency and energy consumption were analyzed for different design parameters,i. e. heating load and primary side water supply temperature. The heating characteristics under off-design conditions were discussed with the mechanism modeling and Ebsilon platform. Results showed that design value of primary side water supply temperature had significant effect on system heat transfer efficiency and energy consumption. The variation of coal rate was 4.56g/kW·h due to the change of primary side water supply temperature.关键词
高背压/热电联产/设计供水温度/系统周期净供电功率/系统周期供电煤耗Key words
high back pressure/cogeneration/design water supply temperature/system power supply during heating period/system coal rate during heating period分类
信息技术与安全科学引用本文复制引用
时斌,王宁玲,李晓恩,张雨檬,杨志平..供水温度对高背压热电联产系统能耗水平的影响[J].化工进展,2018,37(1):96-104,9.基金项目
国家科技支撑计划(2014BAA06B02)及国家重点基础研究发展计划(2015CB251505)项目. (2014BAA06B02)