摘要
Abstract
Objective Using Sysmex XN-20 automatic hematology analyzer to detect the percentage of im-mature platelet fraction (IPF% ) and the absolute number of immature platelet (IPF#) in the peripheral blood , to evaluate the performance of the IPF% and IPF# and establish a reference interval ,to investigate the clini-cal significance in the thrombocytopenic diseases .Methods The performance of the analyzer for detecting IPF% and IPF # was evaluated ,including precision ,stability ,carryover and the linear range ,and correlated with Sysmex XE-5000 detection of IPF% and IPF# .In this research ,240 normal samples were used to form a reference interval and set for negative control group .111 samples of the thrombocytopenic diseases were se-lected as positive group ;Receiver operating characteristic curve between the ITP group and the healthy control group was drawed .Results The within-batch precisions of IPF% and IPF# for normal-level ,high-level were 2 .52% ,2 .32% and 3 .60% ,1 .93% ,the between-batch precisions were 1 .8% and 3 .7% ;the stability of IPF% and IPF# for normal-level were 8 .4% ,8 .8% within 24 hours ,the high-level were 4 .4% ,4 .5% within 24 hours;the carryover of IPF% was 0 .16% ,the carryover of IPF # was 0 .27% ;a linear relation of IPF # was observed from 0 to 94 .8 × 109/L ,which had no statistical difference with Sysmex XE-5000(P>0 .05) .No sta-tistical difference was observed within gender (P>0 .05) ,and the reference interval was determined as IPF% 0 .9% -4 .5% and IPF#(3 .7-9 .7)× 109/L .In idiopathic thrombocytopenic purpura(ITP) group and myelo-dysplastic syndrome(MDS) group ,IPF% had statistical significance compared with healthy control group (P<0 .05);In aplastic anemia (AA ) ,acute lymphoblastic leukemia (ALL ) and acute nonlymphocytic leukemia (AML) group ,IPF# had statistical significance compared with healthy control group (P<0 .05) .The IPF% cut-off for a diagnosis of ITP was 11 .6% ,the sensitivity was 100% and specificity was 100% .Conclusion The determination of IPF% and IPF# by the Sysmex XN-20 have high precision ,good stability ,very low car-ryover and good linear range of the IPF# ,meeting the need of clinical determination ,they have certain clinical application values in the clinical diagnosis ,differential diagnosis and prognosis of the thrombocytopenia dis-ease .关键词
SysmexXN-20全自动血细胞分析仪/未成熟血小板/血小板减少性疾病Key words
Sysmex XN-20 automatic hematology analyser/immature platelet fraction/thrombocyto-penia disease分类
医药卫生