In order to provide basic data for initial rainfall interception control , the first flush effect of non-point source pollution in Guangzhou community unit was studied in this paper .The runoff pollutants at road , roof and greenbelt during three rainfall events in the study area were collected and analyzed .The dimensionless cumulative curve, the first flush coefficient and MFF index were used respectively to do quantitative analysis and qualitative analysis of the first flush effect of runoff pollutants such as BOD 5 , CODCr , TSS, NH3-N, TP and TN.The results showed that the first flush at greenbelt and roof occurred more easily and had more intensity than that at road , and the first flush at greenbelt is more obvious after successive rains .Among the various pollutants in the first flush , the first flush effect of TN is more obvious , and TP and NH 3-N take the second place .The more reliable quantitative results can be obtained by the MFF index method , and it is recommended to be the analysis method of the first flush effect.

关键词

面源污染/初期冲刷效应/无量纲累积曲线/初期冲刷系数/质量初期冲刷强度指数

Key words

non-point source pollution/first flush effect/dimensionless cumulative curve/first flush coefficient/MFF index

分类

资源环境

引用本文复制引用

黄国如,曾家俊,吴海春,张明珠..广州市典型社区单元面源污染初期冲刷效应[J].水资源保护,2018,34(1):8-15,17,9.

基金项目

广州市水务科技项目(GZSW-201401) (GZSW-201401)

广州市科技计划项目(201707020020) (201707020020)

广东省水利科技创新项目(2016-32) (2016-32)

水资源保护

OA北大核心CSCDCSTPCD

1004-6933

访问量0
|
下载量0
段落导航相关论文