计量学报2018,Vol.39Issue(1):83-88,6.DOI:10.3969/j.issn.1000-1158.2018.01.18
直流高压电阻分压器泄漏电流测量研究
Research on Measuring Leakage Current of DC High-voltage Resistive Divider
摘要
Abstract
A device using to measure the leakage current of DC high voltage resistor divider is introduced.The device uses ZigBee wireless communication technology,which by way of an independent power supply to avoid the risk of high voltage electric field resulting in damage to the measuring instrument,and solve issues of difficult to measure the leakage current of the voltage divider in the high voltage state.It can overcome the effect of high voltage power supply ripple and drift by using synchronous sampling method,and the uncertainty of measurement is less than 9.8 × 10-6 V,k =2.关键词
计量学/高压分压器/泄漏电流/电压变差/不确定度Key words
metrology/high voltage divider/leakage current/voltage variation/uncertainty分类
通用工业技术引用本文复制引用
张煌辉,林飞鹏,邵海明,张钟华..直流高压电阻分压器泄漏电流测量研究[J].计量学报,2018,39(1):83-88,6.基金项目
国家质检总局科研计划项目(2013QK042) (2013QK042)