| 注册
首页|期刊导航|传感技术学报|考虑质量吸收系数μm变化的新β射线吸收法 粉尘浓度计算公式研究

考虑质量吸收系数μm变化的新β射线吸收法 粉尘浓度计算公式研究

巫亮

传感技术学报2018,Vol.31Issue(1):74-77,4.
传感技术学报2018,Vol.31Issue(1):74-77,4.DOI:10.3969/j.issn.1004-1699.2018.01.013

考虑质量吸收系数μm变化的新β射线吸收法 粉尘浓度计算公式研究

Study of a New Formula for Dust Concentration on β-Ray Method Joint Changes of Mass Absorb Coefficient μm

巫亮1

作者信息

  • 1. 中煤科工集团重庆研究院有限公司,重庆400037;瓦斯灾害监控与应急技术国家重点实验室,重庆400039
  • 折叠

摘要

Abstract

The effect of suction negative pressure on the mass absorption coefficient μm is not considered separately in the existing β-ray absorption method of dust concentration calculation formula. An algorithm for influencing fac-tors ε of mass absorption coefficient of filter membrane was proposed,and a new method for calculating dust concen-tration is deduced. Contrastive experiments ofβ-ray Method and Standard Weighing Method,the new formula of cal-culating the correlation coefficient increased from 0.975 to 0.986,the average error is decreased from 8% to 3%, Detection accuracy has improved significantly at low concentrations,especially.

关键词

环境污染/β射线/质量吸收系数/粉尘浓度

Key words

environmental pollution/β-ray/mass absorb coefficient/dust concentration

分类

资源环境

引用本文复制引用

巫亮..考虑质量吸收系数μm变化的新β射线吸收法 粉尘浓度计算公式研究[J].传感技术学报,2018,31(1):74-77,4.

基金项目

项目来源:国家重点研发计划课题项目( 2016YFF0102801) ( 2016YFF0102801)

传感技术学报

OA北大核心CSCDCSTPCD

1004-1699

访问量0
|
下载量0
段落导航相关论文