| 注册
首页|期刊导航|广东电力|HM-200型制氢机电解槽温度高故障分析及处理

HM-200型制氢机电解槽温度高故障分析及处理

彭树明

广东电力2018,Vol.31Issue(1):40-43,4.
广东电力2018,Vol.31Issue(1):40-43,4.DOI:10.3969/j.issn.1007-290X.2018.001.008

HM-200型制氢机电解槽温度高故障分析及处理

Fault Analysis and Treatment for High Temperature of Electrolytic Cell in HM-200 Hydrogen Generator

彭树明1

作者信息

  • 1. 广东惠州天然气发电有限公司,广东 惠州516080
  • 折叠

摘要

Abstract

In allusion to the problem of abnormality of system failure in alarm and shutdown due to high temperature of elec-trolytic cell in HM-200 hydrogen generator,the paper analyzes causes for equipment faults.By means of signal simulation method,it tests flexibility of the valve and accuracy of logic.It discovers the cooling water temperature regulating valve is in failure and alarm logic control has disconnected,which leads to high temperature of the electrolytic cell and the system fail-ure in shutdown.The hydrogen generator recovers to normal operation after removing faults.Finally,the paper proposes rectification measures so as to ensure safe and reliable operation of equipment.

关键词

制氢机/氢气/故障/预控措施

Key words

hydrogen generator/hydrogen/fault/preventive measure

分类

能源科技

引用本文复制引用

彭树明..HM-200型制氢机电解槽温度高故障分析及处理[J].广东电力,2018,31(1):40-43,4.

广东电力

OACSTPCD

1007-290X

访问量0
|
下载量0
段落导航相关论文