摘要

Abstract

The scintillator detector plays an important role in the detection of ray energy and arrival time.Aiming at the new domestic cerium bromide(CeBr3)scintillator crys-tal,the experimental system for testing its key performance was established.A fast-coincident timing resolution measurement device was established,and it's found that the timing resolution of the new scintillator detector is 142 ps.And the results show that the decay time of the cerium bromide crystal is 16.8 ns and the rise time is 0.18 ns.The relative light output measurement device was established and tested to obtain the relative light output to NaI(Tl),and the relative light output of the cerium bromide crystal scintillator detector is 161% for 661.66 keV energy ray.At the same time,the energy response of the detector was measured,and the energy resolution is 4.7% for 661.66 keV energy ray.The performance of the novel scintillator crystals made in China was compared with that of aboard cerium bromide crystal and other kinds of scintillator crystals,such as barium fluoride,lanthanum bromide and sodium iodide,and its appli-cation prospect was discussed.

关键词

无机闪烁体/溴化铈闪烁体/时间分辨率/衰减时间/相对光输出

Key words

inorganic scintillator/CeBr3scintillator/timing resolution/decay time/relative light output

分类

能源科技

引用本文复制引用

周倩倩,侯越云,梁珺成,张春生,王仁波..一种新型溴化铈闪烁体探测器性能研究[J].原子能科学技术,2018,52(2):371-377,7.

基金项目

国家重点研发计划资助项目(2016YFF0200800) (2016YFF0200800)

原子能科学技术

OA北大核心CSCDCSTPCD

1000-6931

访问量0
|
下载量0
段落导航相关论文