Abstract
To study the turn-to-turn electric field distribution in 35 kV dry-type air-core reactor,has a great significance on the mechanism of turn-to-turn discharge fault,and improve its reliability.Therefore,this paper carried out the research of turn-to-turn field distribution in dry-type air-core reactor based on the finite element simulations.The analysis results indicated that the intensity of inter-turn electric field in the outer branch is greater than that in the inner branch.The particularity of the electromagnetic field distribution in 35 kV dry-type air-core reactor leads to the result of end inter-turn electric field intensity in each layer of branch is less than that in the middle section.The inter-turn voltage ratio under 10 kHz and 50 Hz is approximately the same.关键词
干式空心电抗器/有限元仿真/电磁场/匝间电场Key words
dry-type air-core reactor/finite element simulation/electromagnetic field/inter-turn electric field引用本文复制引用
彭庆军,姜雄伟,马仪,钱国超,颜冰,邹德旭,周天春..基于有限元方法的35kV干式空心并联电抗器匝间电场分布研究[J].高压电器,2018,54(2):147-152,6.基金项目