In view of the lack of research on the actual error condition and error characteristics of the digital output type DC voltage transformer,an error analysis model of the digital output type DC voltage transformer was established. The field cali-bration test was completed,the actual error condition was obtained,and the error characteristics were analyzed in detail. The re-sults show that:There exists the phenomenon of over tolerance in the digital output type DC voltage transformer,but it can meet the 0.2 level requirements by means of error correction;The linearity of basic errors is about 0.1% to 0.2%;Both the rise and fall variation and the short time stability are 10-4orders of magnitude;The phenomenon of zero drift exists,and the zero correc-tion improves the linearity by 0.08%,as well as enhances the measurement accuracy by 0.1% at 10% rated voltage.

关键词

数字量输出/直流电压互感器/误差特性/误差分析模型/线性度/零点漂移

Key words

digital output/DC voltage transformer/error characteristic/error analysis model/linearity/zero drift

分类

信息技术与安全科学

引用本文复制引用

李登云,雷民,熊前柱,聂琪,沈曙明,章江铭..数字量输出型直流电压互感器的误差特性分析[J].现代电子技术,2018,41(4):119-123,5.

基金项目

国网公司科技项目(JL71-15-042)Project Supported by Science and Technology Project of State Grid Company(JL71-15-042) (JL71-15-042)

现代电子技术

OA北大核心CSTPCD

1004-373X

访问量0
|
下载量0
段落导航相关论文