配准标记点外形对三维图像配准精度影响研究

Influence of registration markers' shape on the registration accuracy of 3D images

吴秦 1赵铱民 2李翔 1白石柱2

作者信息

  • 1. 商丘医学高等专科学校口腔医学系,河南商丘476000
  • 2. 第四军医大学口腔医院修复科,陕西西安710032
  • 折叠

摘要

Abstract

Objective To investigate the influence of the different shape of the registration markers on the registration accuracy of 3D images.Methods Totally 4 kinds of markers with different shapes were used to register the samples' CBCT 3D images to their original 3D images respectively.The distance between the two kinds of 3D images was measured and the effect of different shapes of markers on the registration accuracy of 3D images was analyzed.Results The registration deviation was cubical marker (0.0938 ± 0.0062)mm,spherical marker (0.0854 ± 0.0056)mm,cylindrical marker (0.1032 ± 0.0061) m m,and truncated cone marker (0.0972 ± 0.0062) mm;statistical significance only existed between the spherical marker group and other groups (P < 0.05).Conclusion All of the markers in this experiment can be used to achieve 3D image registration precisely.In comparison,the spherical marker has higher registration accuracy.

关键词

配准/标记点/三维图像/口腔医学

Key words

registration/marker/3D image/stomatology

分类

医药卫生