VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究

王晓明 汤欣 郑秀华

眼科新进展2018,Vol.38Issue(2):153-155,160,4.
眼科新进展2018,Vol.38Issue(2):153-155,160,4.DOI:10.13389/j.cnki.rao.2018.0034

VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究

Comparison of Toric intraocular lens axis marking using VERION image guided system and slit lamp observation

王晓明 1汤欣 2郑秀华1

作者信息

  • 1. 300020天津市,天津医科大学眼科临床学院天津市眼科医院天津市眼科研究所天津市眼科学与视觉科学重点实验室
  • 2. 250200山东省济南市,济南市明水眼科医院
  • 折叠

摘要

Abstract

Objective To evaluate the accuracy and validity of Toric intraocular lens (IOL) alignment by VERION image guided system.Methods In this retrospective study,75 eyes of 75 patients who underwent phacomulsification combined with Toric IOL implantation were enrolled from June 2016 to May 2017.Before operation,anterior segment images of all patients were collected using VERION image guided system,and target axis of IOL implantation was set.Horizontal axis was marked using 1 mL syringe needle under the slit lamp.During the procedures,the IOL was implanted referring to the target axis under VERION system or the slit lamp randomly,and there were 42 eyes with IOL implantation guided by VERION system (VERION group),and 33 eyes guided by slit lamp (slit lamp group).The best corrected visual acuity (BCVA) of each patient was recorded at day 1,1 week,1 month,and 3 months after operation.Anterior segment images were taken after mydriasis,and all the images were analyzed by Photoshop software.Finally,the BCVA at various time points after operation and the deviation value of actual axis and target axis was compared in both groups.Results The proportion of eyes with BCVA ≥ 0.8 at day 1,1 week,1 month,and 3 months after operation was 61.9%,78.6%,71.4% and 76.2% in VERION group,respectively,and 69.7%,78.8%,81.8% and 75.8% in slit lamp group,respectively,and there was no statistical significance between VERION group and slit lamp group (all P > 0.05).The difference value of target axis marked by VERION system and by slit lamp was (3.04 ± 1.99) °.No significant differences were seen in the IOL actual axis and target axis between the two groups at various time points (all P > 0.05).Conclusion It is accurate and stable of VERION image guided system for toric IOL axis marking.

关键词

VERION数字导航系统/角膜散光/轴位标记/白内障/人工晶状体

Key words

VERION image guided system/corneal astigmatism/axis marking/cataract/IOL

分类

医药卫生

引用本文复制引用

王晓明,汤欣,郑秀华..VERION数字导航系统行散光矫正型人工晶状体(Toric IOL)轴位标记与传统裂隙灯标记方法的对比研究[J].眼科新进展,2018,38(2):153-155,160,4.

眼科新进展

OA北大核心CSTPCD

1003-5141

访问量0
|
下载量0
段落导航相关论文