| 注册
首页|期刊导航|压力容器|塔顶冷凝器换热管腐蚀原因分析与预防

塔顶冷凝器换热管腐蚀原因分析与预防

易成 周超

压力容器2018,Vol.35Issue(2):49-53,5.
压力容器2018,Vol.35Issue(2):49-53,5.DOI:10.3969/j.issn.1001-4837.2018.02.008

塔顶冷凝器换热管腐蚀原因分析与预防

Failure Analysis on Heat Exchanger Tubes of Tower Overhead Condenser

易成 1周超1

作者信息

  • 1. 中国五环工程有限公司,湖北武汉 430223
  • 折叠

摘要

Abstract

The corrosion morphology,microstructure and corrosion products of the heat exchanger tubes were studied by the method of optical microscope,scanning electron microscope with EDS and XRD.The reason of corrosion was analyzed.The results show that the uniform corrosion which induced by combined action of H2S-NH3-HCN-H2O occurred and the tubes had been perforated in the serious corrosion ar-ea.Some protective methods were also proposed.

关键词

换热管/腐蚀/失效分析

Key words

heat exchanger tube/corrosion/failure analysis

分类

机械制造

引用本文复制引用

易成,周超..塔顶冷凝器换热管腐蚀原因分析与预防[J].压力容器,2018,35(2):49-53,5.

压力容器

OA北大核心CSTPCD

1001-4837

访问量0
|
下载量0
段落导航相关论文