宫颈癌18F-FDG PET与MR体积测量一致性探讨的PET/MR研究

鲁玥玥 孙洪赞 马全美 辛军

中国临床医学影像杂志2018,Vol.29Issue(2):112-117,129,7.
中国临床医学影像杂志2018,Vol.29Issue(2):112-117,129,7.

宫颈癌18F-FDG PET与MR体积测量一致性探讨的PET/MR研究

The consistency investigation of PET volume and MR volume for the cervical cancer using 18F-FDG PET/MR

鲁玥玥 1孙洪赞 1马全美 1辛军1

作者信息

  • 1. 中国医科大学附属盛京医院放射科,辽宁沈阳 110004
  • 折叠

摘要

Abstract

Objective:In advanced cervical cancer radiotherapy target delineation,tumor volumes auto contoured by FDG PET scan change at different percentages of maximum standardized uptake value (SUVmax).To reduce such effect which interferes from PET and MR image fusion,we attempted to get a cutoff SUVmax at which the tumor volume correlates best with MRI volume on the primary tumors of cervical carcinoma.Methods:Patients with biopsy-proven cervical carcinomas (stages ⅡB and above) were included in this study and underwent pretreatment 18F-FDG PET/MRI.The dimensions were measured by two competent radiologists.Counters of the diseases were drawn in each slice on sagittal T2WI MR images,and volumes of the cervical carcinoma were calculated by tumor area multiplying slice profile.Volumes of the FDG PET scan at 20%~60%(with an interval of 5%) of SUVmax were auto calculated.Mean and median volumes of different SUVmax cutoff percentages on FDG-PET scan were recorded.Pearson correlation was used to analyze the correlation of MR and PET volumes at different thresholds with SPSS 17.0.The mean difference values between PET volumes at different thresholds and MR volumes were calculated,the difference between different SUVmax percentage PET volume and MR volume were analyzed by Student's t test.Results:Data of 20 patients were available for the study.The mean MRI volume of the primary tumor was (40.5±28.0) cm3.The mean MRI volume correlates significantly(P<0.001) with 35% SUVmax PET volume with good correlation according to the Pearson bivariate correlation (r=0.888,r2=0.789).The mean difference between MRI and PET volumes was the least at 35% SUVmax.There was no significant difference in the MRI and FDG-PET volumes obtained with SUVmax cutoff values of 35% SUVmax (P>0.05) according to the Student's t test.Conclusions:18F-FDG PET-MR SUV-based primary tumor volume estimation at 35% SUVmax value correlates significantly with the criterion standard MR T2WI volumes for primary cervical tumor in our population.The difference of 35% SUVmax PET volume with MR T2WI volume is no statistical significance.

关键词

宫颈肿瘤/正电子发射断层显像术/磁共振成像

Key words

Cervix neoplasms/Positron-emission tomography/Magnetic resonance imaging

分类

医药卫生

引用本文复制引用

鲁玥玥,孙洪赞,马全美,辛军..宫颈癌18F-FDG PET与MR体积测量一致性探讨的PET/MR研究[J].中国临床医学影像杂志,2018,29(2):112-117,129,7.

基金项目

辽宁省教育厅重点实验室基础研究项目,LZ2015079. ()

中国临床医学影像杂志

OACSTPCD

1008-1062

访问量0
|
下载量0
段落导航相关论文