CASIA SS-1000OCT与Sirius眼前节分析系统测量角膜厚度的比较

孙成淑 张小兰 黄永志

国际眼科杂志2018,Vol.18Issue(1):153-155,3.
国际眼科杂志2018,Vol.18Issue(1):153-155,3.DOI:10.3980/j.issn.1672-5123.2018.1.38

CASIA SS-1000OCT与Sirius眼前节分析系统测量角膜厚度的比较

Comparison of corneal thickness measured by CASIA SS-1000 OCT and Sirius anterior eye assay system

孙成淑 1张小兰 1黄永志1

作者信息

  • 1. 610000 中国四川省成都市,四川大学华西医院眼科
  • 折叠

摘要

Abstract

AIM:To compare CASIA SS-1000 and Sirius OCT sweep anterior segment analyzer instrument for measuring normal corneal vertex thickness (CCT) and the thinnest corneal thickness (TCT) results the difference,correlation and consistency,and provide a theoretical basis for clinical application.METHODS:This was a prospective study.A total of 34 normal subjects were collected.The subjects were measured by the same skilled operator.The SS-1000 OCT was first used,and then the corneal thickness was measured repeatedly by Sirius anterior segment analyzer.Paired t test and Bland-Altman were used to evaluate the consistency of corneal apex and corneal thinnest point between SS-1000 OCT and Sirius anterior segment analyzer.RESULTS:The mean corneal apex measured by SS-1000 OCT and Sirius corneal topography were 517.62± 25.29μm and 518.47±27.23μm CCT,respectively.The thinnest points of SS-1000 OCT and Sirius anterior segment analyzer CCT were 513.53±25.06μ m and 515.32± 26.69μm,respectively.Paired t test showed that the difference on corneal thickness of vertex was not statistically significant (P>0.05),but the thinnest corneal thickness was statistically significant (P< 0.05).Pearson analysis of the two devices,the correlation is 0.969,0.965.The results of 95% consistency limiting analysis on the corneal vertex thickness by Bland-Altman was (-14.22μm,12.52μm),that of the thinnest corneal thickness was (-15.61μm,12.03μm),4% (3/68) was out of the 95% consistency limiting,but the thinnest corneal thickness was of a little larger differences.CONCLUSION:SS-1000 OCT measurement of CCT and Sirius anterior segment analyzer is highly consistent,in clinical work can be considered alternative,but the thinnest point of the cornea can not be replaced each other.

关键词

眼前节OCT/眼前节分析仪/顶点角膜厚度/最薄点角膜厚度/一致性分析

Key words

CASIA SS-1000 optical coherence tomography/Sirius anterior segment analyzer/center corneal thickness/thinnest corneal thickness/consistency analysis

引用本文复制引用

孙成淑,张小兰,黄永志..CASIA SS-1000OCT与Sirius眼前节分析系统测量角膜厚度的比较[J].国际眼科杂志,2018,18(1):153-155,3.

国际眼科杂志

OA北大核心CSTPCD

1672-5123

访问量0
|
下载量0
段落导航相关论文