大坝安全监测自动化系统人工比测的精度指标法

卢正超 姜云辉 黎利兵

水力发电2018,Vol.44Issue(3):94-97,4.
水力发电2018,Vol.44Issue(3):94-97,4.

大坝安全监测自动化系统人工比测的精度指标法

Sensor Accuracy Standard for the Comparison of Manual and Automated Measurements in Dam Safety Monitoring

卢正超 1姜云辉 2黎利兵1

作者信息

  • 1. 中国水利水电科学研究院,北京100038
  • 2. 流域水循环模拟与调控国家重点实验室,北京100038
  • 折叠

摘要

Abstract

In order to ensure the accuracy and reliability of automated measurements,the comparison with manual measurements by readouts calibrated on a regular basis is mandatory.It is stipulated that the variance analysis should be used as a quantitative means in the assessment of automated dam safety monitoring system in Chinese specifications and codes.However,it is found that the suggested 2o criteria of variance analysis method is actually not suitable for the comparison of manual and automated measurements because the variance of manual and automated measurements is either too big for long-term series or too small for short-term series to be the reliable criteria.It is proposed that the sensor accuracy standard should be used instead as the criteria for the assessment of automated dam safety monitoring system.It means that the difference between the manual and automated measurements should be judged on the basis of the accuracy of the sensors.Some suggestions are also made on the modification of the Chinese specifications related to automated dam safety monitoring.

关键词

监测自动化/人工比测/方差分析法/精度指标法

Key words

automated monitoring/comparison of manual and automatic measurements/variance analysis/sensor accuracy standard

分类

建筑与水利

引用本文复制引用

卢正超,姜云辉,黎利兵..大坝安全监测自动化系统人工比测的精度指标法[J].水力发电,2018,44(3):94-97,4.

基金项目

国家重点研发计划资助项目(2016YFC0401809,2016-YFC0401600) (2016YFC0401809,2016-YFC0401600)

水力发电

OA北大核心CSTPCD

0559-9342

访问量0
|
下载量0
段落导航相关论文