| 注册
首页|期刊导航|物理学报|中波红外微型静态傅里叶变换光谱仪的设计与分析

中波红外微型静态傅里叶变换光谱仪的设计与分析

王洪亮 吕金光 梁静秋 梁中翥 秦余欣 王维彪

物理学报2018,Vol.67Issue(6):64-75,12.
物理学报2018,Vol.67Issue(6):64-75,12.DOI:10.7498/aps.67.20172599

中波红外微型静态傅里叶变换光谱仪的设计与分析

Design and analysis of medium wave infrared miniaturestatic Fourier transform spectrometer

王洪亮 1吕金光 2梁静秋 1梁中翥 1秦余欣 1王维彪1

作者信息

  • 1. 中国科学院长春光学精密机械与物理研究所, 应用光学国家重点实验室, 长春 130033
  • 2. 中国科学院大学, 北京 100049
  • 折叠

摘要

Abstract

This paper presents a spatial modulation Fourier transform micro-spectrometer based on micro-optical elements. The infrared microstructure diffractive optical elements, multi-step micro-mirrors and microlens array are introduced to realize the miniaturization of the instrument. In addition, the structure and basic principle of Fourier transform infrared micro-spectrometer are introduced. The design theory of micro-collimation system is analyzed based on the negative dispersion, the abberation correction and the arbitrary phase modulation characteristics of diffractive optical element. Combined with the characteristics of micro-static interference system, the micro-focusing coupled optical system is analyzed and designed. Based on the wave aberration theory and the Sellmeier dispersion formula, the influence of residual aberration on spectral recovery and the diffraction efficiency of diffraction surface in single-chip hybrid diffractive-refractive collimating lens are studied. The effects of diffraction of multi-stage micro-mirrors and the aperture diffraction of microlens array on spectral recovery are studied by using the scalar diffraction theory. Furthermore, the influence of axial assembly error of relay system on the whole system performance is studied. The results show that the diffraction efficiency of the diffraction surface, the diffraction of the multistage micro-mirror and the microlens array have no effect on the recovery spectrum when the working band of the system is 3.7–4.8 μm. Finally, in order to verify the accuracy of the system design results, an optical simulation software is used to simulate the infrared micro-Fourier transform spectrum. The accuracy of the system model is verified by the simulation that the reconstructed spectrum is in agreement with the ideal spectral curve and the actual spectral recovery error is 2.89%. The medium-wave infrared micro-static Fourier transform spectrometer has no movable parts and adopts micro-optics element to replace the traditional infrared lens. Therefore, it has the advantages of not only good stability, but also small size and light weight so that it is helpful in on-line monitoring applications and provides a new design idea about the micro-Fourier transform spectrometer.

关键词

中波红外傅里叶变换光谱仪/衍射微结构/微透镜阵列

Key words

medium wave infrared Fourier transform spectrometer/diffraction microstructure/microlens array

引用本文复制引用

王洪亮,吕金光,梁静秋,梁中翥,秦余欣,王维彪..中波红外微型静态傅里叶变换光谱仪的设计与分析[J].物理学报,2018,67(6):64-75,12.

基金项目

国家自然科学基金(批准号: 61575193, 61627819, 61376122, 6173000222, 61727818)、吉林省科技发展计划(批准号:20170204077GX, 20150204072GX, 20150520101JH, 20150101049JC)和中国科学院创新促进会基金(批准号: 2014193)资助的课题. Project supported by National Nature Science Foundation of China (Grant Nos. 61575193, 61627819, 61376122, 6173000222, 61727818), the Science and Technology Development Plan of Jilin Province, China (Grant Nos. 20170204077GX, 20150204072GX, 20150520101JH, 20150101049JC), and the State Key Laboratory of Applied Optics Independent Fund and Youth Innovation Promotion Association Chinese Academy of Sciences (Grant No. 2014193). (批准号: 61575193, 61627819, 61376122, 6173000222, 61727818)

物理学报

OA北大核心CSCDCSTPCDSCI

1000-3290

访问量0
|
下载量0
段落导航相关论文