中国医疗设备2018,Vol.33Issue(3):6-10,5.DOI:10.3969/j.issn.1674-1633.2018.03.002
基于加速度波形形态分析的胸外按压深度检测研究
Study on the Detection of Chest Compressions Based on Acceleration Waveform Shape Analysis
摘要
Abstract
Objective In this paper, a new method of depth detection of chest compressions based on acceleration waveform morphological analysis was presented to simplify the hardware requirements for press depth testing during cardiopulmonary resuscitation and made it easier to use and popularize in clinic. Methods The miniature accelerometer was used to acquire acceleration signal during chest compressions. Then the serial peripheral interface interface was used to transfer the data in real time to the ARM controller. After the data was preprocessed, the starting and ending points of the pressing was found through the analysis of the shape of the acceleration waveform during the pressing process. Then we calculated the depth of the pressing by the second integral. Results From the results of three preset depths of compression, we proved that the depth of pressure measurement could be achieved within ±0.93 mm with 95% confidence. Conclusion The depth of compression can simplify the hardware requirements, and the accuracy of this method can also meet the clinical needs to detect the depth of compression.关键词
加速度传感器/加速度波形分析/二次复位积分/心肺复苏/按压深度检测Key words
acceleration sensor/acceleration waveform analysis/second reset integral/cardiopulmonary resuscitation/press depth detection分类
医药卫生引用本文复制引用
吴豪杰,吴水才,刘忠英..基于加速度波形形态分析的胸外按压深度检测研究[J].中国医疗设备,2018,33(3):6-10,5.基金项目
国家自然科学基金资助项目(71661167001 ()