| 注册
首页|期刊导航|医疗卫生装备|一种新型骨折外固定装置的设计和实验验证

一种新型骨折外固定装置的设计和实验验证

刘申 梁向党 王歆淏 胡传忠 郭占社 孙赓

医疗卫生装备2018,Vol.39Issue(2):34-36,3.
医疗卫生装备2018,Vol.39Issue(2):34-36,3.DOI:10.7687/j.issn1003-8868.2018.02.034

一种新型骨折外固定装置的设计和实验验证

Design and experimental study of new type of external fixation device for bone fracture

刘申 1梁向党 1王歆淏 1胡传忠 1郭占社 2孙赓3

作者信息

  • 1. 解放军总医院骨科,北京100853
  • 2. 北京航空航天大学仪器科学与光电工程学院,北京100191
  • 3. 解放军252医院骨科,河北保定071000
  • 折叠

摘要

Abstract

Objective To design a new type of external fixator for bone fracture and verify its rationality and feasibility. Methods The frame and screw of stainless steel achieved fracture fixation in vitro with a threaded locking structure.At the same time the increasing thickness of body frame, the inclined nail holes and the raised bottoms were designed to greatly enhance the strength and overall stability of body frame.FEM (finite element method),measuring the relative displacement and stress distribution after axial load,was used to verify the rationality of the design.An animal experiment with sheep was used to verify the feasibility of fracture treatment. Results Simulated result of FEM indicated that the biggest relative displacement between the separated bones was 0.04 mm,which was much less than the minimum value 1 mm required for fracture healing.The maximum stresses applied on the frame of the fixator,fixator screw,and bone were 35,26,and 6 MPa, respectively, which was much less than the allowable stress. In the animal experiment, fracture site was fixed firmly after operation and was well cured 3 months later.Conclusion The design of this new device is feasible and it can be used as a new method of fracture treatment.

关键词

骨折/外固定装置/有限元分析/应力/愈合

Key words

fracture/external fixation device/FEM/stress force/healing

分类

医药卫生

引用本文复制引用

刘申,梁向党,王歆淏,胡传忠,郭占社,孙赓..一种新型骨折外固定装置的设计和实验验证[J].医疗卫生装备,2018,39(2):34-36,3.

基金项目

军队医药卫生科技成果扩试项目(01012604) (01012604)