照明工程学报2017,Vol.28Issue(6):66-69,4.DOI:10.3969/j.issn.1004-440X.2017.06.012
普通照明用自镇流LED灯的频闪问题分析
Analysis of Flicker Problem of Self-Ballasted LED Lamps for General Lighting Services
薛晓晓 1陈萍 1王建1
作者信息
- 1. 浙江省电子信息产品检验所,浙江杭州310007
- 折叠
摘要
Abstract
We tested 80 batches self-ballasted LED lamps for general lighting services we bought or obtained from manufactories,adopting the test items in 2 international mainstream technology specification of flicker.We were trying to find out the existing status of flicker problems on the market.In this paper,we analyze the two specifications to conclude their unity and differences from the principles and the test results.关键词
照明/自镇流LED灯/频闪/闪烁百分比/SVM指数Key words
self-ballasted LED lamps for general lighting services/flicker/percent flicker/NM/Pst/SVM分类
信息技术与安全科学引用本文复制引用