长江科学院院报2017,Vol.34Issue(12):22-27,6.DOI:10.11988/ckyyb.20161274
西安地区浅层承压水水源热泵适宜性评价
Suitability Evaluation for Shallow Confined Water Source Heat Pump in Xi'an
摘要
Abstract
A suitability evaluation system for shallow confined water source heat pump in Xi'an is constructed in consideration of thirteen factors including water abundance,reinjection efficiency,hydraulic conductivity,and aquifer thickness.The weight of each factor is determined by using analytic hierarchy process method and Gini coefficient method.In addition,GIS technology is employed to build up a two-level evaluation model for spatial analysis,and the suitabihty of the study area is divided into four levels.Results reveal that the area of favorable region for constructing water source heat pump system in the study area is 1144.32 km2,the area of suitable region is 1393.57 km2,the area of moderately suitable region is 762.48 km2,and the area of unsuitable region is 6807.63 km2.The total area of suitable region is 3300.36 km2,accounting for 76.98% of the human activity area,indicating that shallow confined water source heat pump has a good prospect in Xi'an city.关键词
地下水源热泵/层次分析法/基尼系数赋权法/GIS技术/适宜性评价/西安市Key words
groundwater source heat pump/analytic hierarchy process/weight determination according to Gini co-efficient/GIS technology/suitability evaluation/Xi'an city分类
能源科技引用本文复制引用
赖光东,周维博,姚炳光..西安地区浅层承压水水源热泵适宜性评价[J].长江科学院院报,2017,34(12):22-27,6.基金项目
陕西水利科技计划项目(2014slkj-19) (2014slkj-19)