电气传动2018,Vol.48Issue(2):23-28,46,7.DOI:10.19457/j.1001-2095.20180204
变频软开关及优化负电流的四相交错耦合双向DC-DC变换器
Four-phase Interleaved Coupled Bidirectional DC-DC Converter with Variable-frequency in Soft Switching and Optimization of the Negative Current
摘要
Abstract
Aiming at single-phase half-bridge bidirectional DC-DC,its operational modal and resonant process were analyzed in Buck mode.The control strategy to implement variable-frequency in soft-switching was discussed;Discussion on soft-switching and optimal negative current control when the high side and low side work in different circumstances of Buck mode of the single-phase half-bridge bidirectional DC-DC was carried out;A four-phase interleaved soft-switching bidirectional DC-DC converter of optimization negative current variable-frequency control with combination of coupled inductor was proposed.Experimental results show that,compared with fixed-frequency control,the new variable-frequency and optimization of the negative current control strategy improves converter efficiency greatly,improve the inductor current ripple.关键词
双向DC-DC/软开关/变频控制策略/最优负电流Key words
bidirectional DC-DC/soft switching/variable-frequency control strategy/optimal negative current分类
信息技术与安全科学引用本文复制引用
周映虹,廖胜峰,程明谊..变频软开关及优化负电流的四相交错耦合双向DC-DC变换器[J].电气传动,2018,48(2):23-28,46,7.基金项目
广东新能源汽车专项(110105752020190) (110105752020190)
广东省科技计划项目(2013B011301011) (2013B011301011)
广州市科技计划(201604016084) (201604016084)