首页|期刊导航|肿瘤预防与治疗|肺癌患者CT肺动脉成像优化扫描研究

肺癌患者CT肺动脉成像优化扫描研究

李海烈 何长久 肖乾坤 周鹏 胡仕北 刘舫

肿瘤预防与治疗2017,Vol.30Issue(6):442-447,6.
肿瘤预防与治疗2017,Vol.30Issue(6):442-447,6.DOI:10.3969/j.issn.1674-0904.2017.06.009

肺癌患者CT肺动脉成像优化扫描研究

Study of Optimized Scan on Computed Tomography Pulmonary on Patients with Lung Cancer

李海烈 1何长久 1肖乾坤 1周鹏 1胡仕北 1刘舫1

作者信息

  • 1. 610041成都,四川省肿瘤医院·研究所,四川省癌症防治中心,电子科技大学医学院影像科
  • 折叠

摘要

Abstract

Objective:To explore optimized scan on CT pulmonary angiography (CTPA) on patients with lung cancer by reducing the tube voltage and tube current.Methods:Sixty of suspected pulmonary embolism patients with lung cancer were randomly divided into three groups.The patient underwent CT pulmonary angiography in 3 scanning protocols with different tube voltage and tube current,experimental group 1 (120 KV 、200 mAs),experimental group 2 (120 KV、100 mAs),experimental group 3 (80 KV、200 mAs).X-ray quantity of X,the number of photons was said by product of tube current mA and irradiation time s,mAs.A subjective scoring system for image quality,image noise and image sharpness was conducted by 2 radiologists independently.The measured values(pulmonary artery CT value and noise) as well as the calculated values[signal-to-noise(SNR) and contrast-to-noise (CNR)] were compared between among 3 protocols.Results:There was no significant differences in subjective scores of the image quality,image noise and image sharpness(P was 0.158,0.123,0.256,respectively,were > 0.05),all of the scores were three points or more.There was significant differences in CT value and noise of pulmonary artery in all protocols (P < 0.05),the CT value and noise of pulmonary artery experimental group 3 were the largest,the CT value of pulmonary artery in experimental group 2 was minimum.The SNR and CNR of pulmonary artery experimental group 2 and 3 were reduced,there was no significant differences in SNR and CNR between experimental group 2 and 3.The radiation doses of all protocols(372.73-±29.76、200.33 ± 16.90、127.59 ± 15.70) mGy.cm,experimental group 2 and 3 were reduced,the radiation dose of experimental group 3 was minimum.Conclusion:Compared with reducing tube current,reducing tube voltage could obviously increase pulmonary artery enhanced value and sharply reduce radiation dose,although the noise increased,but the image quality of CTPA could meet the diagnostic requirements.Experimental group 3 (80 KV 、200 mAs) could be used optimized scan on CTPA.

关键词

肺癌/肺动脉栓塞/CT肺动脉成像/辐射剂量

Key words

Lung cancer/Pulmonary embolism/CT pulmonary angiography/Radiation dose

分类

医药卫生

引用本文复制引用

李海烈,何长久,肖乾坤,周鹏,胡仕北,刘舫..肺癌患者CT肺动脉成像优化扫描研究[J].肿瘤预防与治疗,2017,30(6):442-447,6.

基金项目

四川省科技计划项目(编号:2014JY0240) (编号:2014JY0240)

成都市科技惠民项目(编号:2014-HM01-00189-SF) (编号:2014-HM01-00189-SF)

肿瘤预防与治疗

OACSTPCD

1674-0904

访问量4
|
下载量0
段落导航相关论文