| 注册
首页|期刊导航|中国电力|基于模糊综合评判的变压器套管绝缘状态评估

基于模糊综合评判的变压器套管绝缘状态评估

李志超 李卫国 夏喻 张书琦 汤浩 贾鹏飞 陈绍君

中国电力2018,Vol.51Issue(4):22-26,60,6.
中国电力2018,Vol.51Issue(4):22-26,60,6.DOI:10.11930/j.issn.1004-9649.20160400

基于模糊综合评判的变压器套管绝缘状态评估

Insulation Condition Assessment of Transformer Bushing Based on Fuzzy Comprehensive Evaluation

李志超 1李卫国 2夏喻 1张书琦 1汤浩 3贾鹏飞 3陈绍君3

作者信息

  • 1. 华北电力大学 电气与电子工程学院,北京 102206
  • 2. 国网北京通州供电公司,北京 101149
  • 3. 中国电力科学研究院,北京 100192
  • 折叠

摘要

Abstract

To solve the problem that overall assessment of transformer is too general, a fuzzy comprehensive evaluation model is constructed for transformer bushing insulation condition assessment. Due to the fact that constant weight may cause distorted evaluation, the variable weight is introduced to make the evaluation results close to the actual condition of transformer bushing, and the semi-trapezoid distribution function is adopted as a membership function to determine the fuzzy matrix. The ranking eigenvalue is used as a comprehensive rank to determine the condition level of transformer bushing. The case study verifies that the fuzzy comprehensive evaluation is reliable and practical for transformer bushing condition assessment.

关键词

变压器套管/状态评估/模糊综合评判/绝缘状态/变权

Key words

transformer bushing/condition assessment/fuzzy comprehensive evaluation/insulation condition/variable weight

分类

信息技术与安全科学

引用本文复制引用

李志超,李卫国,夏喻,张书琦,汤浩,贾鹏飞,陈绍君..基于模糊综合评判的变压器套管绝缘状态评估[J].中国电力,2018,51(4):22-26,60,6.

基金项目

国家电网公司科技项目(SGFJDK00DWJS1500069).This work is supported by Science and Technology Program of State Grid Corporation of China(No.SGFJDK00DWJS1500069). (SGFJDK00DWJS1500069)