| 注册
首页|期刊导航|中华耳科学杂志|人工耳蜗植入经耳蜗造孔注射药物对NRT阈值的影响

人工耳蜗植入经耳蜗造孔注射药物对NRT阈值的影响

江采晔 卓明英 吴倩倩 韦玉琴 陈肇臻 杨育儒

中华耳科学杂志2018,Vol.16Issue(2):193-198,6.
中华耳科学杂志2018,Vol.16Issue(2):193-198,6.DOI:10.3969/j.issn.1672-2922.2018.02.013

人工耳蜗植入经耳蜗造孔注射药物对NRT阈值的影响

Does Intra-cochlear Infusion After Cochleostomy for Cochlear Implantation Affect Neural Response Telemetry Thresholds

江采晔 1卓明英 1吴倩倩 1韦玉琴 1陈肇臻 1杨育儒1

作者信息

  • 1. 厦门长庚医院耳鼻咽喉头颈外科 厦门361028
  • 折叠

摘要

Abstract

Objective We aimed to compare neural response telemetry(NRT)thresholds in children receiving co-chlear implants with or without intra-cochlear dexamethasone(DXM)or hyaluronic acid(HA)infusion upon cochleosto-my as priming substances.Methods This was a hospital based study of pediatric cochlear implant(CI)patients during the period between June 2015 and January 2016 at Changgeng Memorial Hospital(CGMH),Xiamen,China.The NRT software was administered to 75 operated ears in 73 children(mean age at implantation:4.1 years)via pre-curved Co-chlear Nucleus electrodes.The patients were divided in to 3 groups based on intra-cochlear infusion:i.e.DXM(Group DXM,n=26),HA(Group HA,n=20)and no priming agents infusion(Group N,n=29).Five intra-cochlear elec-trodes (number 1 and 6 for high frequency, number 11 for mid frequency, and number 16 and 22 for low frequency) were tested intraoperatively and at initial device activation at two weeks post-operatively.One-way analysis of variance (ANOVA)was used to compare the number of activated electrodes and mean NRT thresholds in the 3 groups.Paired t test and Wilcoxon test were applied to analyze NRT thresholds changes from intraoperative testing and initial activation. Differences in the rate of no-response low and high frequency electrodes among the 3 groups were tested by Pearson χ2 test.Results There was no statistically significant difference in the mean NRT threshold among the 3 groups intraopera-tively or at device activation(P=0.13 and 0.77 respectively),although thresholds for basal turn electrodes in the DXM group were lower.In all 3 groups,the intraoperative mean NRT threshold was higher than that at initial device activa-tion.Conclusions The rate of no-response electrodes during operation and at initial switch-on was similar with or with-out dexamethasone/hyaluronic acid priming.High frequency electrodes at basal turn,when primed with dexamethasone, appear to yield lower response thresholds.

关键词

人工耳蜗植入/地塞米松/透明质酸

Key words

Cochlear Implantation/Dexamethason/Hyaluronic Acid

分类

医药卫生

引用本文复制引用

江采晔,卓明英,吴倩倩,韦玉琴,陈肇臻,杨育儒..人工耳蜗植入经耳蜗造孔注射药物对NRT阈值的影响[J].中华耳科学杂志,2018,16(2):193-198,6.

基金项目

厦门市科技惠民计划(3502Z20174030) Science and technology for benefiting people project of Xiamen(3502Z20174030) (3502Z20174030)