Abstract

Existing glare measurement methods can not clearly identify the point where the maximum UGR of illumination space is located,and the measured UGR value is not necessarily the maximum value of the space,and the measurement work is complicated. In order to quickly and accurately measure the UGR value of illumination space, this paper proposes a method to set UGR measurement point first and then measure UGR by using Dialux evo software simulation, and then validates the method in darkroom. The experimental results show that this method can not only reduce the number of measurement points to be set, reduce the cumbersome measurement work, but also obtain the maximum UGR value of the measured space.

关键词

眩光/测量/Dialuxevo仿真/统一眩光指数/照明

Key words

glare/measurement/Dialux evo software simulation/UGR/lighting