| 注册
首页|期刊导航|玻璃钢/复合材料|CFRP蒙皮-CFRP胶接质量的原位超声检测技术

CFRP蒙皮-CFRP胶接质量的原位超声检测技术

高晓进 周金帅 江柏红

玻璃钢/复合材料Issue(4):32-38,7.
玻璃钢/复合材料Issue(4):32-38,7.

CFRP蒙皮-CFRP胶接质量的原位超声检测技术

ON-EQUIPMENT ULTRASONIC TESTING TECHNOLOGY OF BONDING QUALITY OF CFRP SKIN-CFRP

高晓进 1周金帅 1江柏红1

作者信息

  • 1. 航天特种材料及工艺技术研究所,北京 100074
  • 折叠

摘要

Abstract

According to the characteristics of the bonded structure of CFRP skin-CFRP,short pulse ultrasonic reflecting on-equipment testing method was used to test bonding quality,the influence of bonding film and debonding in structure on ultrasonic reflecting signal were analyzed,and self made short pulse delay block ultrasonic probe was used to test debonding in samples.Simulation results show that,short pulse ultrasonic reflecting signal can test Ⅰ interface debonding Ⅱ interface debonding when d/λ ≤0.5.Experiment results show that,the width of pulse produced by self made 5 MHz probe is not larger than 1.5 cycle,which can meet the requirement of short pulse.The self made probe can test Ⅰ interface debonding,and Ⅱ interface debonding when thickness of bonding film is less than 0.5 mm,which can meet on-equipment testing requirement of actual product.

关键词

胶结/超声/原位检测/脱粘

Key words

bonding/ultrasonic/on-equipment testing/debonding

引用本文复制引用

高晓进,周金帅,江柏红..CFRP蒙皮-CFRP胶接质量的原位超声检测技术[J].玻璃钢/复合材料,2018,(4):32-38,7.