Abstract
According to the standard method of atomic fluorescence for determination of arsenic in the water, three sets of calibration curves were given at three different temperatures 10℃、20℃、30℃, and the linear correlation coefficients were 0.999 80、0.999 25、0.999 89. Three blank samples were tested at three different temperatures, and the detection limits were 0.02 μg/L、0.01 μg/L、0.01 μg/L, which met the requirements. Three standard samples were tested at three different temperatures, the test results met the quality control requirements at 10℃、20℃, but some of the test results did not meet the quality control requirements and accuracy requirements at 30℃.关键词