计量学报2018,Vol.39Issue(3):405-409,5.DOI:10.3969/j.issn.1000-1158.2018.03.24
线缆分析仪远端衰减串音比参数的校准方法研究
Research on Calibration Method of Cable Analyzer in Far-end Attenuation-to-Crosstalk Ratio Parameter
摘要
Abstract
Far-end attenuation-to-crosstalk ratio (ACR-F) is the primary parameter of digital balanced cable,also the essential test item in cable analyzer.Have proposed a calibration method on ACR-F of cable analyzer,which utilize network analyzer (NA) and impedance converter to measure insertion loss (IL) and far-end crosstalk (FEXT) in reference cable separately,and acquire the derived results.And the calibration method of ACR-F is direct comparison between the NA and cable analyzer on the reference cable.The method is confirmed through comparison with Psiber(R) Wirexpert series cable analyzer,and extended uncertainty is also listed.关键词
计量学/远端衰减串音比/线缆分析仪/插入损耗/远端串扰Key words
metrology/ACR-F/cable analyzer/cnsertion loss/far-end cross-talk分类
通用工业技术引用本文复制引用
陈龙泉,许伟,黄震,张颖艳..线缆分析仪远端衰减串音比参数的校准方法研究[J].计量学报,2018,39(3):405-409,5.基金项目
国家科技重大专项(2015ZX03001011) (2015ZX03001011)
国家重点研发计划(2016YFF0200104) (2016YFF0200104)