起重运输机械Issue(4):118-122,5.
变极调速起重机空气开关跳闸机理分析
摘要
Abstract
A tripping fault tree model is established for air switch of crane trolley to analyze tripping fault. Investigation has found that tripping results from inter-phase short circuit of motor with contactors turned on at the same time. To eliminate safety hazards in control equipment of the trolley and pole-changing control mode, the paper proposes corresponding measures for hardware protection and software design improvement so as to ensure safer and more reliable crane.关键词
起重机/跳闸/空气开关/变极调速Key words
crane/tripping/air switch/pole-changing control分类
机械制造引用本文复制引用
刘军,刘艳群,林春明,梁旭..变极调速起重机空气开关跳闸机理分析[J].起重运输机械,2018,(4):118-122,5.