| 注册
首页|期刊导航|眼科新进展|角膜补偿眼压(IOPcc)和5种眼压校正公式所得校正眼压的一致性及IOPcc、模拟Goldmann眼压与眼球各参数的相关性分析

角膜补偿眼压(IOPcc)和5种眼压校正公式所得校正眼压的一致性及IOPcc、模拟Goldmann眼压与眼球各参数的相关性分析

罗保根 张晓峰 钱一峰

眼科新进展2018,Vol.38Issue(5):457-460,4.
眼科新进展2018,Vol.38Issue(5):457-460,4.DOI:10.13389/j.cnki.rao.2018.0106

角膜补偿眼压(IOPcc)和5种眼压校正公式所得校正眼压的一致性及IOPcc、模拟Goldmann眼压与眼球各参数的相关性分析

Agreement between corneal-compensated intraocular pressure (IOPcc) and five corrected intraocular pressures and the correlation of ocular biometries with IOPcc and Goldmann correlated intraocular pressure

罗保根 1张晓峰 1钱一峰1

作者信息

  • 1. 215000 江苏省苏州市,苏州大学附属第一医院眼科
  • 折叠

摘要

Abstract

Objective To compare the agreement between corneal-compensated intraocular pressure (IOPcc) measured by ocular response analyzer (ORA) and 5 corrected intraocular pressures from Sirius anterior system,and analyze the correlation of ocular biometries with IOPcc and Goldmann-correlated IOP (IOPg).Methods Together 90 eyes of 90 patients,aged 18-37 (24.47 ± 5.57) years,without refractive surgery contraindications undergoing myopic laser treatment were enrolled in this study.Each eye was measured 3 times by Sirius anterior system,with the best results of IOPcc and IOPg was selected.And patients' corneal biomechanical parameters were measured using an ORA (Reichert,Inc.,USA).The IOPg from ORA were entered into the 5 IOP formulas embedded in Sirius anterior system to generate the corrected IOPs,which were recorded as the Dresdner corrected IOP,Ehlers corrected IOP,Kohlhaas corrected IOP,Orssengo/Pye corrected IOP and Shah corrected IOP,accordingly.Meanwhile the agreement of the 5 corrected IOPs and the IOP measured non-contact tonometer with IOPcc was analyzed,respectively.Corneal biomechanics,including corneal hysteresis and corneal resistance factor,and ocular biometries were also recorded,and the correlation of these parameters with IOPcc and IOPg was assessed with correlation coefficient.Resuits The pair comparison of IOPcc and Kohlhaas corrected IOP was statistically significant (P < 0.05).Dresdner corrected IOP and Orssengo/Pye corrected IOP showed a good agreement with IOPcc,and the 95% limits of agreements (LoA) were (-2.09 ~2.55)mmHg (1 kPa=7.5 mmHg) and (-2.38~2.37) mmHg,respectively.The 95%LoA of Dresdner's corrected IOP and IOPcc was the narrowest.No statistical significance was found between IOPcc and corneal hysteresis,corneal resistance factor,ocular biometries,but there was a positive correlation between IOPg and corneal resistance factor,central corneal thickness,and corneal volume (all P < 0.05).Conclusion Dresdner and Orssengo/Pye corrected IOP had a good agreement with IOPcc,and most ocular biometries have a little effect on IOPcc.

关键词

Sirius眼前节分析系统/眼反应分析仪/眼压/青光眼/近视

Key words

Sirius anterior system/ocular response analyzer/intraocular pressure/glaucoma/myopia

分类

医药卫生

引用本文复制引用

罗保根,张晓峰,钱一峰..角膜补偿眼压(IOPcc)和5种眼压校正公式所得校正眼压的一致性及IOPcc、模拟Goldmann眼压与眼球各参数的相关性分析[J].眼科新进展,2018,38(5):457-460,4.

眼科新进展

OA北大核心CSTPCD

1003-5141

访问量0
|
下载量0
段落导航相关论文