肾脏弛豫率的参考值及其与不同场强的相关性

黄海波 李艳兰 林莹 管俊 覃明 黄桂雄

广西医学2018,Vol.40Issue(9):1028-1033,6.
广西医学2018,Vol.40Issue(9):1028-1033,6.DOI:10.11675/j.issn.0253-4304.2018.09.08

肾脏弛豫率的参考值及其与不同场强的相关性

Reference range of renal relaxation rate and its correlation with different magnetic field intensities

黄海波 1李艳兰 2林莹 1管俊 1覃明 1黄桂雄1

作者信息

  • 1. 中国人民解放军第三○三医院影像科,南宁市 530021
  • 2. 广西民族医院放射科,南宁市 530001
  • 折叠

摘要

Abstract

Objective To explore the reference range of renal relaxation rate(R2?) and its correlation with different magnetic field intensities.Methods A total of 105 volunteers were divided into group A(n=90) and group B(n=15).Group A received MRI scanning using Philips Healthcare System(3.0T),while group B received MRI scanning using Siemens Healthcare System(3.0T) and Philips Healthcare System(1.5T),with a two-hour scanning interval.The water phantom scanning was performed using the three MRI scanners above before and after the volunteers′ scanning.Multiple gradient-echo(T2?) sequence was collected,and the R2? values of phantom,renal cortex and medulla were determined among the volunteers. The R2? values of kidney/phantoms were compared among different field intensities,or among different MRI scanners.The correlation of the reference range of R2?values with different field intensities was analyzed.Results Before and after the volunteers′scanning,the R2? values of phantoms acquired by 3.0T Siemens Scanner and 3.0T Philips Scanner were higher than that by 1.5T Philips Scanner(all P<0.05),and there was a rectilinear correlation between R2?values of phantoms acquired by 3.0T Siemens Scanner and 1.5T Philips Scanner(r=0.995,P<0.05).The medullary R2?value was higher than the cortical value among the 100 volunteers(P<0.05).The medullary and cortical R2? values acquired by 3.0T Siemens Scanner and their difference value were higher than those by 1.5T Philips Scanner(P<0.05),and no correlation was found between the medullary or cortical R2? values acquired by 3.0T Siemens Scanner and 1.5T Philips Scanner(P>0.05).Conclusion The R2?value of renal medulla is higher than that of renal cortex,there is no correlation among the renal R2?values scanned with different field intensities,however,a high correlation is seen among phantom the R2? values scanned with different field intensities.

关键词

弛豫率/肾脏/磁共振成像/场强/相关性

Key words

Relaxation rate/Kidney/Magnetic resonance imaging/Field intensity/Correlation

分类

医药卫生

引用本文复制引用

黄海波,李艳兰,林莹,管俊,覃明,黄桂雄..肾脏弛豫率的参考值及其与不同场强的相关性[J].广西医学,2018,40(9):1028-1033,6.

基金项目

广西医药卫生科研课题(Z2016518) (Z2016518)

广西医学

OACSTPCD

0253-4304

访问量0
|
下载量0
段落导航相关论文