电测与仪表2018,Vol.55Issue(11):41-44,57,5.
0.4kV配电网无功补偿多点配置研究
Research on reactive power compensation multi-point configuration of 0.4 kV distribution network
赵前扶 1于擎 2王圣钧 2张恩硕2
作者信息
- 1. 东北电力大学电气工程学院,吉林吉林132012
- 2. 国网通化供电公司,吉林通化134000
- 折叠
摘要
Abstract
Aiming at the problem of reactive power compensation in low voltage distribution network,a reactive power compensation optimization model with the minimum net loss as the objective function is established,and the improved interior model is used to solve the optimization model in the process of optimization.And in view of the allocation of compensation device in the distribution of low-pressure side of the root point can not solve the low-voltage distribution network loss and so on,the optimization method of reactive power compensation device with multi-point distribution on the low-voltage side of the distribution transformer is proposed,the model is solved by using the improved interior point method with all the load nodes as the compensation points,taking into account the economy of compensation and easy maintenance and other factors,several final compensation points for reactive power compensation device configuration are selected after obtaining the ideal configuration program.The feasibility and practicability of the method are analyzed and verified by the actual low-voltage distribution network.关键词
低压配电网/改进内点法/无功优化/多点补偿Key words
low voltage distribution network/improved interior point method/reactive power optimization/multi-point compensation分类
信息技术与安全科学引用本文复制引用
赵前扶,于擎,王圣钧,张恩硕..0.4kV配电网无功补偿多点配置研究[J].电测与仪表,2018,55(11):41-44,57,5.