宫颈癌容积旋转调强放疗中不同弧数目计划间的 剂量学差异

Dosimetric differences between volumetric modulated arc therapy plans with different arc numbers for cervical cancer

龙雨松 1谭军文 1王占宇 1贺先桃 1梁卫学1

作者信息

  • 1. 广西医科大学第四附属医院肿瘤科放疗室,广西柳州 545005
  • 折叠

摘要

Abstract

Object To study the effects of the number of arcs in the treatment of cervical cancer with volumetric modulated arc therapy (VMAT) on the treatment plan, and to provide reference for the selection of the number of arcs in the clinical application.Methods CT images of 10 patients with cervical cancer were selected, it's the radiation therapist that delineated the target area and organs, the prescribed dose was 5040 cGy per 28 times to the target area, and single arc (Arc1), double arc (Arc2) and three (Arc3) plan were designed by RayStation planning system to compare the differences with the dosimetry characteristics of target and organs. The time required for planning optimization was recorded, and the difference between the monitor unit and the delivery time in the three plans was analyzed. A dose validation tool for PTW was used to verify the dose to analyze the influence of the number of arc on the passing rate of gamma verification.Results Single arc plan (Arc1), double arc plan (Arc2) and three arc plan (Arc3) for 10 cases of cervical cancer all proved to meet the clinical requirements. With the increase of arc number, the target area distribution got improved, V40, V45 and Dmean in the organs at risk of rectum, bladder, and femoral head gradually decreased in case of doses of 40 and 45 Gy, and V35, V40 and V45 in the normal tissue were lowered in case of the doses of 35, 40 and 45 Gy. With the increase of the arc number, the optimization time and the delivery time of the plan increased, while the difference between the monitor unit of the three plans was smaller. The passing rate of the three plans was more than 99.5%, and the difference was small.Conclusion Cervical cancer VMAT plan has the target dose distribution and the protection of organs at risk enhanced with the increase of the number of arcs, while the treatment time and cost increased. Therefore, it is necessary to take comprehensive considerations on the number of VMAT plan arcs.

关键词

宫颈癌/容积旋转调强放疗/弧数目/剂量学/危及器官/靶区

Key words

cervical cancer/volumetric modulated arc therapy/arc number/dosimetry/organ at risk/target area

分类

医药卫生

引用本文复制引用

龙雨松,谭军文,王占宇,贺先桃,梁卫学..宫颈癌容积旋转调强放疗中不同弧数目计划间的 剂量学差异[J].医疗卫生装备,2018,39(6):58-62,71,6.

医疗卫生装备

OACSTPCD

1003-8868

访问量0
|
下载量0
段落导航相关论文