| 注册
首页|期刊导航|川北医学院学报|生活饮用水中三氯甲烷、四氯化碳含量测定改良法

生活饮用水中三氯甲烷、四氯化碳含量测定改良法

刘迎春 陈杰 罗霞 伍建 黄亚婷

川北医学院学报2018,Vol.33Issue(3):461-463,3.
川北医学院学报2018,Vol.33Issue(3):461-463,3.DOI:10.3969/j.issn.1005-3697.2018.03.043

生活饮用水中三氯甲烷、四氯化碳含量测定改良法

Improved method of chloroform and carbon tetrachloride determination in drinking water

刘迎春 1陈杰 1罗霞 1伍建 1黄亚婷1

作者信息

  • 1. 德阳市疾病与预防控制中心,四川 德阳 618000
  • 折叠

摘要

Abstract

Objective:To improve a capillary column headspace-gas chromatographic method for simultaneous determination of chloroform and carbon tetrachloride in drinking water. Methods:Added sodium chloride in the driect sampling in headspace bottle,dis-solve and mix,and separated with a HP-5 capillary column (30 m×0. 32 mm,0. 25 μm),the oven temperature was 50 ℃,the column flow rate was 1. 0 mL/min,the injection inlet temperature was 190 ℃,the split ratio was 3∶ 1,and detected by ECD detector (230℃). Results:The linear ranges of chloroform and carbon tetrachloride were 0. 1~10 μg/L,and the correlation coefficients were more than 0. 999. The detection limits of the method were 0. 001 2~0. 012 μg/L. The average recoveries were 96. 5% ~106. 2% . The rela-tive standard deviations within day were 3. 0% ~5. 1% (n=7),respectively. Conclusion:The method is simple,quick,sensitive and accurate with good reproducibility,and it is suitable for the simultaneous determination of chloroform and carbon tetrachloride in drink-ing water .

关键词

生活饮用水/三氯甲烷/四氯化碳/毛细管柱/顶空气相色谱法

Key words

Drinking water/Chloroform/Carbon tetrachloride/Capillary column/Headspace-Gas chromatography

分类

医药卫生

引用本文复制引用

刘迎春,陈杰,罗霞,伍建,黄亚婷..生活饮用水中三氯甲烷、四氯化碳含量测定改良法[J].川北医学院学报,2018,33(3):461-463,3.

川北医学院学报

OACSTPCD

1005-3697

访问量0
|
下载量0
段落导航相关论文