摘要

Abstract

A high field asymmetrical waveform ion migration spectrometric(FAIMS) method was developed for the determination of benzene in water. The benzene standard spectra in different dispersion voltages(DV) were studied, and the second-order α2 and the fourth-orderα4 coefficients of nonlinear function for benzene identification were calculated to be-3.8 x 10-5 Td-2 and 5.1 x 10-8 Td-4, respectively. The optimum dispersion voltage for benzene identification was obtained to be 800 V by balancing the sensitivity and resolution. The detection limit of FAIMS for benzene in water, through the relationship between benzene signal intensity and different benzene concentrations (0.08-0.64 mg/L), was determined to be 0.89μg/L, which was far superior to the national concentration limit(10μg/L) for benzene in drinking water. This study provides a rapid and sensitive method for the detection of benzene in water.

关键词

高场不对称波形离子迁移谱(FAIMS)/现场检测//水样

Key words

high field asymmetrical waveform ion migration spectrometry(FAIMS)/field detection/benzene/water

分类

化学化工

引用本文复制引用

石海峡,徐青,余健文,胡俊,陈池来..高场不对称波形离子迁移谱快速检测水样中苯含量[J].分析测试学报,2018,37(6):744-748,5.

基金项目

国家重点研发计划(2016YFC0201101,2016YFC0201102) (2016YFC0201101,2016YFC0201102)

合肥物质科学技术中心创新项目培育基金(2016FXCX008) (2016FXCX008)

中国科学院青年创新促进会资助项目(2013213) (2013213)

分析测试学报

OA北大核心CSCDCSTPCD

1004-4957

访问量0
|
下载量0
段落导航相关论文